Accept the classic principle of injection incineration, low nitrogen incinerator sells to connect atmosphere, master initiatively, incineration science, etc., low nitrogen incinerator enables methanol fuel to obtain sufficient incineration (ask higher customers to choose silicon carbide tube); subdue the fuel application with more impurities such as crude methanol and waste methanol after secondary filtration, so as to prevent the production of infarction and pump body damage Raw, completely disconnected high-pressure pump body pressure atomization!
1. High heat compliance: special incinerator for alcohol based fuel, low nitrogen incinerator selling self-supporting R & D double-layer tangential cyclone system, reasonable layout, abundant incineration, high heat compliance; 2. High safety: when the boiler is started, the incinerator will light a small fire first, when the small fire is usually consolidated, the alcohol based incinerator, the automatic control system will open the main gas valve, and the fuel gas will come into the boiler for normal incineration Burning, will not produce deflagration signs; 3, burning methanol fuel atomization is good, less energy consumption, low noise; 4, flame consolidation, burning subject to high, little pollution to the situation; 5, the placement is reliable, all active control.
Pipes and cockcrows: comb tubes, low nitrogen incinerators with the amount of air tubes to keep each incinerator piped and applied. Cocks are used to control the movement of gas through pipelines. Copper oxide incineration tube: one incineration is carried out in a quartz tube, in which the thicker capillary of the tube is compared with the other end of the glass tube, and the center one side of the end with a smaller diameter is larger than that of the easily packed particle copper oxide. In order to burn the copper oxide tube evenly, it can be placed in one side of the incinerator with two sides, one thermocouple or the upper half of the branch tube inserted in the thermometer to master the incineration temperature.
Low nitrogen incinerator is sold on schedule for protection: 1. All light diesel oil must be clean. Please pay attention to flushing the oil tank and oil filter on schedule. 2. Under normal application, change the oil nozzle once a year, and change the elastic coupling and rubber parts on the coupling once a year and a half. 3. Foreign matters are not allowed to enter the air duct. 4. Combustibles and explosives shall be kept away from the application site of the incinerator, and there shall be extinguishing buildings. 5. Adjust the oil pressure according to the oil pressure. 6. Search and inspect the incinerator, impeller, flame detector and combustion electrode on schedule, and remove the oil and carbon deposits. In particular, the flame detector shall be clean and free from water. 7. Cut off the power supply when protecting the incinerator.
The fuel sample shall be extracted from the fuel barrel, so as to provide accurate appearance of low nitrogen incinerator sales. The commissioning of the incinerator is based on the sampling information of the incineration flue gas. Any adjustment to the atmosphere and fuel oil will affect the flue gas emissions. The flue gas factors can be studied to explain the compliance of incineration. The incineration products and their causes are listed below. A disciplined method of incinerator protection is very necessary to avoid work stoppage and extend the life of the incineration system. Connecting the steps listed above with the initiatives proposed by the low nitrogen incinerator vendors can determine a useful protection method. In this way, not only will it become lost due to the hindrance of work stoppage and after-sales service, but it will also improve the incineration to comply with the thrifty fuel cost.
Main fan - check whether the inlet of the main fan is installed with protective assembly, whether things meet the requirements, and repair the leakage on the fan. The low nitrogen incinerator shall investigate the condition of blades during operation to see if there is too much noise and vibration. If there are these signs, the blades can be adjusted to eliminate them. The crude oil to be heated begins to enter the convection chamber tube of the incinerator, and the crude oil temperature is generally 29. The heat of the furnace tube is obtained from the flue gas flowing through the convection chamber by convection method. The heat is transferred from the external surface of the furnace tube to the internal surface of the furnace tube by heat transfer method, and then transferred to the active crude oil in the tube by convection method.
The ultra-low nitrogen incinerator factory inquired that the reason for the explosion of the furnace during operation is that the atmosphere is not enough and the gas burning is not complete. In the flue gas of the furnace, the gas will explode when it reaches a certain concentration. This kind of situation often occurs in the heating furnace of low nitrogen incinerator with forced ventilation. In the process of application, the fuel oil incinerator will inevitably encounter questions. It is commonly used in small and medium-sized fuel boiler, fuel hot air blower, drying (baking) box and small fuel heating furnace. The efficiency of the incinerator can be completed after the increase of construction, but the incinerator in many industrial sites does not satisfy the requirements of burning and heating or feedback.
——Author:ebico