According to its efficiency, components and associated components of incinerator can be divided into six efficiency systems: main body layout, master system, combustion system, fuel supply system, incineration system and energy system.
I. main layout
This one side constitutes the main layout and surface of the incinerator. The utility model comprises a shell and associated spare parts, and the products on the other efficacy systems are all arranged on the main body layout.
2. Department of mastery
The one-sided products include master, servo mechanism (motor and hydraulic cylinder), flame monitor, pressure or temperature switch, etc. Mastering device: the focus of mastering the incinerator is one-sided, including the process of the proportional regulator, the master of management, the gas leak detector that is working hard to check the leakage point of the valve, etc., all of which are working hard to collect and trigger the light signals of each action, matching the brain of the incinerator. Frequently used brands include Siemens, Brahma, Honeywell, etc. In this case, Siemens is widely imitated, and its simulation level is high. As the editor of the staff in the industry, most of the 400 loa24 ordered in 2004 are products of * *. Servo mechanism: all electric servo motors and machine driven hydraulic cylinders belong to the master system. The reason is that the former and the French master form a closed-loop master system, and the energy source of the latter comes from the oil pump. The actual action command is triggered by the master, and the opening and closing of the damper is mastered. At present, this product has not been completely imitated in China, but it is said that it has not been seen. Flame monitor: this title has been further deviated from its actual efficacy title by the popular name in the industry. It is not always different from the master type. It is a pure experience. The master who can master the opening and closing of the device is complex. It can only monitor the flame reality, including photoresist and phototube, and the ion probe which can test the flame ion. If it can turn on and off the power supply by itself, it should be called palm The grip is more suitable. Just as in all industries, all buyers only pay very little for the equipment of * * *, while all sellers only pay more for the equipment with less cost. After all, what is the basis of the subject matter, not only no one pays attention to it, but also creates a small section. Qrb1, qrb3, qra2, fc13 and other large-scale products in the photoelectric cell are all used by the government. In this case, qrb1 has been widely matched due to its solid quality. The editor has not seen qrb1 of Siemens for three years. Pressure and temperature switch: it should be called pressure or temperature sensor in a broad sense. The gas switch in the pressure switch: gas switch, which is mostly used to master the gas of gas incinerator, and the wind pressure switch is used to master the atmosphere (if there is no wind pressure caused by forced air supply, the power supply of the whole machine is cut off). The temperature switch is mainly used to control the heating temperature of high viscosity fuel, such as heavy oil or residual oil.
III. combustion system
The one-sided products include combustion transformer, combustion electrode and high-voltage wire. Combustion transformer: it is used to generate high-voltage current and undergo electrode discharge as the product of combustion of incinerator. This is a product with low technology content, and it is used as a device to imitate the product with low technology content. Combustion electrode: not to mention the products with technical content. Unless the style is too unique and the use is too small, the editor will not store the original products, nor initiate user applications. High voltage line: it's just a high-temperature and high-voltage power line. Why the entrance? Not to mention the original one.
Department of energy
In the frequently used incinerator, only the electric idea should be related to the energy.
V. fuel supply system
In the incinerator, this is one of the more cumbersome systems. In fact, the mechanical products involved in this system are much more cumbersome than the electrical products in the control system. Oil pump, nozzle, fuel heater, oil cup, oil pipe, fuel solenoid valve, gas valve (including gas solenoid valve), gas pressure regulator, gas filter
Vi. incineration Department
Incinerator industry has a very technical system. In reality, no matter what kind of technology the electrical products or oil pumps are produced, the ruggedness of these technical levels has nothing to do with the skill of the incinerator factory itself, but the plan of the incineration system must be regenerated independently. Therefore, the level of the incineration Department determines the talent of an incinerator. This one-sided product includes an incinerator, a forced air blower impeller, a flame disc, an oil gun, an air core tube, and a built-in or external dispersion armour. This one-sided product constitutes the air-fuel premixed assembly.
——Author:ebico